    • 摘要: 负压波技术是管道泄漏监测的有效手段。为获取更精确的负压波拐点信息,提高信噪比,采用102.8 m管道实验平台,根据不同环境下传感器监测负压波信号,对光纤传感器与传统电子压力传感器在响应时间、静态稳定性、抗电磁干扰等方面进行了对比实验分析。实验结果表明,在同等的管道工况下,光纤传感器从泄漏负压波信号的获取到压力信号的重新恢复稳定约需30 ms,远优于电子传感器500 ms的响应时间。在静态稳定性实验中,光纤传感器压力信号输出稳定,压力波动范围±0.001 MPa,远小于电子传感器压力输出变化±0.006 MPa。综合评价分析表明,光纤传感器具有良好的稳定性及抗电磁干扰性能,在管道泄漏监测及能源、化工等领域有着广阔的应用前景。

       

      Abstract: Abstract: Negative pressure wave technique is an effective method for pipeline leak detection. In order to obtain more accurate inflection point information of negative pressure wave and improve signal to noise ratio, experiments using 102.8 meters pipeline experimental platform, according to the negative pressure wave signal captured by the sensors, the response time, static stability and anti-electromagnetic interference of the optical fiber sensor and the traditional electronic pressure sensor are analyzed. Experimental results show that from the leakage of negative pressure wave signal acquisition to the pressure signal restore stability, optical fiber sensor takes about 30 ms, which is far better than the electronic sensor 500 ms. In the static stability experiment, the pressure signal output of optical fiber sensor is stable, and the pressure fluctuation range is ± 0.001 MPa, which is far less than the electronic sensor ± 0.006 MPa. Comprehensive evaluation analysis shows that the optical fiber sensor has good stability and anti-electromagnetic interference performance, and has wide application prospect in the fields of pipeline leakage monitoring, energy and chemical industry.